Schneider TeSys LADN22 Front Auxiliary Contact Block, 2NO + 2NC

Submit your RFQ. Our team will send a quotation confirming price and availability.

Schneider Electric LADN22 is a front-mounted TeSys Deca auxiliary contact block with 2NO + 2NC instantaneous contacts for compatible contactors and control relays. Screw-clamp terminals support control and signalling wiring. Its 10A thermal rating is separate from the voltage-dependent AC-15 and DC-13 switching ratings. The contactor or control relay is selected separately.

Submit your RFQ. Our team will send a quotation confirming price and availability.

Get Your Discount code

Get a special discount when you buy from our store via an exclusive discount code

Share this product:

Model

LADN22

Type

TeSys Deca instantaneous auxiliary contact block

Contact composition

2NO + 2NC

Mounting location

Front

Operation

Instantaneous

Range compatibility

TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F

Rated operational voltage (Ue)

690VAC, 25–400Hz

AC-15 operational current

6A at 120VAC; 1.04A at 690VAC

DC-13 operational current

0.55A at 125VDC; 0.1A at 600VDC

Conventional free-air thermal current (Ith)

10A at 60°C; distinct from utilization-category switching ratings

Insulation voltage (Ui)

690V IEC 60947-5-1; 600V UL/CSA

Minimum switching load

5mA / 17V

Rated making capacity

140A AC / 250A DC, IEC 60947-5-1

Short-time rating at 60°C

100A for 1s; 120A for 500ms; 140A for 100ms

Associated protection

10A gG fuse per manufacturer specification

Mechanical durability

30 million cycles

Single-conductor terminals

1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end

Two-conductor terminals

2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible

Terminal torque

1.7Nm

Dimensions (H × W × D)

48 × 44 × 42mm

Protection degree

IP20, IEC 60529

Operating / storage ambient

−5 to +60°C / −60 to +80°C

Operating altitude

3000m

Colour

Dark grey

Standards

EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1

NO/NC non-overlap

1.5ms on energisation and de-energisation

Net weight

50g

Schneider TeSys LADN22 Front Auxiliary Contact Block, 2NO + 2NC

Schneider Electric LADN22 is a front-mounted TeSys Deca auxiliary contact block with 2NO + 2NC instantaneous contacts for compatible contactors and control relays. Screw-clamp terminals support control and signalling wiring. Its 10A thermal rating is separate from the voltage-dependent AC-15 and DC-13 switching ratings. The contactor or control relay is selected separately.

Key specifications

  • Model: LADN22
  • Type: TeSys Deca instantaneous auxiliary contact block
  • Contact composition: 2NO + 2NC
  • Mounting location: Front
  • Operation: Instantaneous
  • Range compatibility: TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F
  • Rated operational voltage (Ue): 690VAC, 25–400Hz
  • AC-15 operational current: 6A at 120VAC; 1.04A at 690VAC
  • DC-13 operational current: 0.55A at 125VDC; 0.1A at 600VDC
  • Conventional free-air thermal current (Ith): 10A at 60°C; distinct from utilization-category switching ratings
  • Insulation voltage (Ui): 690V IEC 60947-5-1; 600V UL/CSA
  • Minimum switching load: 5mA / 17V
  • Rated making capacity: 140A AC / 250A DC, IEC 60947-5-1
  • Short-time rating at 60°C: 100A for 1s; 120A for 500ms; 140A for 100ms
  • Associated protection: 10A gG fuse per manufacturer specification
  • Mechanical durability: 30 million cycles
  • Single-conductor terminals: 1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end
  • Two-conductor terminals: 2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible
  • Terminal torque: 1.7Nm
  • Dimensions (H × W × D): 48 × 44 × 42mm
  • Protection degree: IP20, IEC 60529
  • Operating / storage ambient: −5 to +60°C / −60 to +80°C
  • Operating altitude: 3000m
  • Colour: Dark grey
  • Standards: EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1
  • NO/NC non-overlap: 1.5ms on energisation and de-energisation
  • Net weight: 50g

Official Schneider Electric datasheet

Submit your RFQ. Our team will send a quotation confirming price and availability.

Model

LADN22

Type

TeSys Deca instantaneous auxiliary contact block

Contact composition

2NO + 2NC

Mounting location

Front

Operation

Instantaneous

Range compatibility

TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F

Rated operational voltage (Ue)

690VAC, 25–400Hz

AC-15 operational current

6A at 120VAC; 1.04A at 690VAC

DC-13 operational current

0.55A at 125VDC; 0.1A at 600VDC

Conventional free-air thermal current (Ith)

10A at 60°C; distinct from utilization-category switching ratings

Insulation voltage (Ui)

690V IEC 60947-5-1; 600V UL/CSA

Minimum switching load

5mA / 17V

Rated making capacity

140A AC / 250A DC, IEC 60947-5-1

Short-time rating at 60°C

100A for 1s; 120A for 500ms; 140A for 100ms

Associated protection

10A gG fuse per manufacturer specification

Mechanical durability

30 million cycles

Single-conductor terminals

1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end

Two-conductor terminals

2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible

Terminal torque

1.7Nm

Dimensions (H × W × D)

48 × 44 × 42mm

Protection degree

IP20, IEC 60529

Operating / storage ambient

−5 to +60°C / −60 to +80°C

Operating altitude

3000m

Colour

Dark grey

Standards

EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1

NO/NC non-overlap

1.5ms on energisation and de-energisation

Net weight

50g