بلوك ملامسات مساعدة أمامي شنايدر TeSys LADN20 بتكوين 2NO

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Schneider Electric LADN20 is a front-mounted TeSys Deca auxiliary contact block with 2NO instantaneous contacts for compatible contactors and control relays. Screw-clamp terminals support control and signalling wiring. Its 10A thermal rating is separate from the voltage-dependent AC-15 and DC-13 switching ratings. The contactor or control relay is selected separately.

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Get Your Discount code

Get a special discount when you buy from our store via an exclusive discount code

Share this product:

Model

LADN20

Type

TeSys Deca instantaneous auxiliary contact block

Contact composition

2NO

Mounting location

Front

Operation

Instantaneous

Range compatibility

TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F

Rated operational voltage (Ue)

690VAC, 25–400Hz

AC-15 operational current

6A at 120VAC; 1.04A at 690VAC

DC-13 operational current

0.55A at 125VDC; 0.1A at 600VDC

Conventional free-air thermal current (Ith)

10A at 60°C; distinct from utilization-category switching ratings

Insulation voltage (Ui)

690V IEC 60947-5-1; 600V UL/CSA

Minimum switching load

5mA / 17V

Rated making capacity

140A AC / 250A DC, IEC 60947-5-1

Short-time rating at 60°C

100A for 1s; 120A for 500ms; 140A for 100ms

Associated protection

10A gG fuse per manufacturer specification

Mechanical durability

30 million cycles

Single-conductor terminals

1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end

Two-conductor terminals

2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible

Terminal torque

1.7Nm

Dimensions (H × W × D)

48 × 26 × 42mm

Protection degree

IP20, IEC 60529

Operating / storage ambient

−5 to +60°C / −60 to +80°C

Operating altitude

3000m

Colour

Dark grey

Standards

EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1

Schneider TeSys LADN20 Front Auxiliary Contact Block, 2NO

Schneider Electric LADN20 is a front-mounted TeSys Deca auxiliary contact block with 2NO instantaneous contacts for compatible contactors and control relays. Screw-clamp terminals support control and signalling wiring. Its 10A thermal rating is separate from the voltage-dependent AC-15 and DC-13 switching ratings. The contactor or control relay is selected separately.

Key specifications

  • Model: LADN20
  • Type: TeSys Deca instantaneous auxiliary contact block
  • Contact composition: 2NO
  • Mounting location: Front
  • Operation: Instantaneous
  • Range compatibility: TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F
  • Rated operational voltage (Ue): 690VAC, 25–400Hz
  • AC-15 operational current: 6A at 120VAC; 1.04A at 690VAC
  • DC-13 operational current: 0.55A at 125VDC; 0.1A at 600VDC
  • Conventional free-air thermal current (Ith): 10A at 60°C; distinct from utilization-category switching ratings
  • Insulation voltage (Ui): 690V IEC 60947-5-1; 600V UL/CSA
  • Minimum switching load: 5mA / 17V
  • Rated making capacity: 140A AC / 250A DC, IEC 60947-5-1
  • Short-time rating at 60°C: 100A for 1s; 120A for 500ms; 140A for 100ms
  • Associated protection: 10A gG fuse per manufacturer specification
  • Mechanical durability: 30 million cycles
  • Single-conductor terminals: 1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end
  • Two-conductor terminals: 2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible
  • Terminal torque: 1.7Nm
  • Dimensions (H × W × D): 48 × 26 × 42mm
  • Protection degree: IP20, IEC 60529
  • Operating / storage ambient: −5 to +60°C / −60 to +80°C
  • Operating altitude: 3000m
  • Colour: Dark grey
  • Standards: EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1

Official Schneider Electric datasheet

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Model

LADN20

Type

TeSys Deca instantaneous auxiliary contact block

Contact composition

2NO

Mounting location

Front

Operation

Instantaneous

Range compatibility

TeSys D / Deca CAD and LC1D; TeSys F LC1F and CR1F

Rated operational voltage (Ue)

690VAC, 25–400Hz

AC-15 operational current

6A at 120VAC; 1.04A at 690VAC

DC-13 operational current

0.55A at 125VDC; 0.1A at 600VDC

Conventional free-air thermal current (Ith)

10A at 60°C; distinct from utilization-category switching ratings

Insulation voltage (Ui)

690V IEC 60947-5-1; 600V UL/CSA

Minimum switching load

5mA / 17V

Rated making capacity

140A AC / 250A DC, IEC 60947-5-1

Short-time rating at 60°C

100A for 1s; 120A for 500ms; 140A for 100ms

Associated protection

10A gG fuse per manufacturer specification

Mechanical durability

30 million cycles

Single-conductor terminals

1–4mm² rigid without cable end; 1–4mm² flexible with/without cable end

Two-conductor terminals

2 × 1–4mm² rigid or unferruled flexible; 2 × 1–2.5mm² ferruled flexible

Terminal torque

1.7Nm

Dimensions (H × W × D)

48 × 26 × 42mm

Protection degree

IP20, IEC 60529

Operating / storage ambient

−5 to +60°C / −60 to +80°C

Operating altitude

3000m

Colour

Dark grey

Standards

EN/IEC 60947-5-1; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1