قاطع حماية محرك شنايدر TeSys GV2 GV2ME04 ثلاثي بمدى 0.4–0.63 أمبير

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Schneider Electric GV2ME04 is a three-pole TeSys GV2 thermal-magnetic motor circuit breaker with an adjustable 0.4–0.63 A thermal-protection range. It combines motor overload and short-circuit protection, phase-failure sensitivity and push-button operation.

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Get Your Discount code

Get a special discount when you buy from our store via an exclusive discount code

Share this product:

Model

GV2ME04

Range

TeSys GV2

Poles

3P

Thermal adjustment

0.4–0.63 A

Trip unit

Thermal-magnetic

Magnetic tripping current

9.3 A

Rated operational voltage

690 V AC, 50/60 Hz, IEC 60947-2

Ultimate breaking capacity

100 kA Icu at 400–415 V AC, IEC 60947-2; other voltages have separate ratings

Control

Push-button

Power connections

Screw clamp terminals

Phase-failure sensitivity

Yes, IEC 60947-4-1

Protection degree

IP20, IEC 60529

Dimensions (H × W × D)

89 × 45 × 78.5 mm

GTIN/EAN

3389110343014

Schneider TeSys GV2 GV2ME04 3P 0.4–0.63A Motor Circuit Breaker

Schneider Electric GV2ME04 is a three-pole TeSys GV2 thermal-magnetic motor circuit breaker with an adjustable 0.4–0.63 A thermal-protection range. It combines motor overload and short-circuit protection, phase-failure sensitivity and push-button operation.

Key specifications

  • Model: GV2ME04
  • Range: TeSys GV2
  • Poles: 3P
  • Thermal adjustment: 0.4–0.63 A
  • Trip unit: Thermal-magnetic
  • Magnetic tripping current: 9.3 A
  • Rated operational voltage: 690 V AC, 50/60 Hz, IEC 60947-2
  • Ultimate breaking capacity: 100 kA Icu at 400–415 V AC, IEC 60947-2; other voltages have separate ratings
  • Control: Push-button
  • Power connections: Screw clamp terminals
  • Phase-failure sensitivity: Yes, IEC 60947-4-1
  • Protection degree: IP20, IEC 60529
  • Dimensions (H × W × D): 89 × 45 × 78.5 mm
  • GTIN/EAN: 3389110343014

Official Schneider Electric datasheet

أرسل طلب عرض السعر، وسيزوّدك فريقنا بعرض يؤكد السعر والتوفر.

Model

GV2ME04

Range

TeSys GV2

Poles

3P

Thermal adjustment

0.4–0.63 A

Trip unit

Thermal-magnetic

Magnetic tripping current

9.3 A

Rated operational voltage

690 V AC, 50/60 Hz, IEC 60947-2

Ultimate breaking capacity

100 kA Icu at 400–415 V AC, IEC 60947-2; other voltages have separate ratings

Control

Push-button

Power connections

Screw clamp terminals

Phase-failure sensitivity

Yes, IEC 60947-4-1

Protection degree

IP20, IEC 60529

Dimensions (H × W × D)

89 × 45 × 78.5 mm

GTIN/EAN

3389110343014

Scroll to Top